QUAD system – This facility is used to perform tests in a vertical direction on the largest or heaviest specimens. The force is provided by four 160kN shakers. The specimen is fixed to the shakers by means of a magnesium QUAD-head expander with an outside dimension of more than 3m. Engineers designed the alignment and guidance system of the QUAD assembly especially to reduce parasitic movement of the specimen in all conditions. The QUAD-head expander is judiciously ribbed to provide a good rigidity/mass ratio and also to provide good transmission of the forces delivered by the four shakers. It is provided with an additional pneumatic load-compensation device which gives the assembly a static load capacity of 10,000 kg.
The safety of the test object is a matter of prime importance for all test activities. Vibration tests involve high energy so every effort has been made to offer the maximum guarantees of safety. All shakers are controlled by a high performance digital control console designed for easy programming of the various test modes.
In combination with the remote control system and interlock circuitry, the console controls all functions of both the power amplifiers and the shakers on the one side and the shakers on the other. It provides timely information on any deviations from normal conditions and ensures the immediate shutdown of the system in a predetermined and controlled manner should the need arise – ensuring the safety of both the test object and the facility.
The system is able to record, monitor and control up to 40 channels in real time and can accommodate most kinds of sensors used in vibration testing (such as piezoelectric, ICP, Teds or voltage output sensors). A digital data recorder records the time history of all the channels connected to the control system to provide back-up in case of anomaly. The responses of the specimen are recorded by a separate Mechanical Data handling system.